Fire-rated ceilings
A fire-rated ceiling is a tested ceiling system that holds back fire for a stated time, usually 30 or 60 minutes, protecting either the void above or the structure. That is different from the reaction-to-fire class every ceiling tile carries.

How we do it
Every ceiling lining must meet the reaction-to-fire rules in Approved Document B, with stricter classes in corridors and escape routes. Most mineral fibre tiles meet those easily. Fire resistance is a separate, higher bar: the whole build-up of grid, tiles or boards, hangers and any fixings is tested together to BS EN 1364-2 or as part of a floor, and only that tested combination gets the rating.
We install fire-rated ceilings strictly to the manufacturer's tested specification, including hold-down clips, hanger centres and how light fittings and openings are protected, and we hand over the product data so your fire strategy and Building Control file are complete.
What's involved
- 30 and 60-minute systems in grid or MF form
- Reaction-to-fire classes to BS EN 13501-1
- Fire resistance classified to BS EN 13501-2
- Hold-down clips and protected openings where the system requires
- Product data and installation records handed over
Best for: Corridors and escape routes, protected voids, schools, healthcare and multi-tenant buildings.
What happens after you get in touch
Send the details
Room size, postcode and what you want done, through the form, the guide-price tool, phone or WhatsApp.
Free survey
We measure, check the soffit, void depth and services, and agree the finished height and tile.
Fixed written quote
Named grid and tile products, programme, working hours, and exactly what is included.
Fit and hand over
Setting out, grid, services coordination and tiles, then a clean room and the product data.
Questions people ask
Are all suspended ceilings fire-rated?
No. Most tiles have a good reaction-to-fire class, but fire resistance only applies to a complete system tested and installed as specified. Ask for the tested system reference.
Can I put normal light fittings in a fire-rated ceiling?
Only if the system allows it, usually with fire hoods or protected fittings. Unprotected openings can void the rating.
Who decides if we need a fire-rated ceiling?
Your fire strategy, fire engineer or Building Control. We can quote to their specification and point out where a tested system will meet it.